41.9. tsn_stmid_frer_ingress
41.9.1. Overview
This example shows TSN frame identification and redundant transmission (IEEE802.1 CB)
Observe the result of the frame identification
After frame passes a successful identification, a incremented sequence number will be generated by STMID module, and then a R-Tag will be added by FRER module.
Redundant Transmission can be implemented by multi-cast mechanism
Due to the limitated hardware design of the development board, this feature is not shown (There is no frame splitting functionality in TSW peripheral. )
At the receiving end, run the sample tsn_stmid_frer_egress on another development board and observe the results of frame recovery
41.9.2. Board Settings
Connect a USB port on PC to the PWR DEBUG port on the development board with a USB Type-C cable
Connect an Ethernet port on PC to a RGMII port on the development board with an Ethernet cable
41.9.3. Project Configurations
None
41.9.4. Run Example
Compiling and Downloading
Running log is shown in the serial terminal as follows:
This is a TSW demo: CB Stmid Frer Ingress TSW phy init passed ! Link Status: Down Link Status: Up Link Speed: 1000Mbps Link Duplex: Full duplex Stream Match Count: 1, SeqNo: 1 Stream Match Count: 2, SeqNo: 2 Stream Match Count: 3, SeqNo: 3 Stream Match Count: 4, SeqNo: 4 Stream Match Count: 5, SeqNo: 5 Stream Match Count: 6, SeqNo: 6